Endeavour™ Ductless Fume Hood - Sliding Sash

Endeavour™ Ductless Fume Hood - Sliding Sash

Variable airflow monitoring and control to ensure efficient operation

 

PRODUCT DESCRIPTION

 

FEATURES

  • Touch-screen microprocessor control with variable airflow controller and constant filter monitoring
  • ChemMinder™ chemical class confirmation - user notification of chemical/filtration compatibility
  • AirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood
  • Dual wall construction allows for front mounting of services such as water, gas, or electric
  • Large capacity filtration bed to handle a wide variety of applications
  • Constant monitoring of fume hood face velocity with variable airflow control to user preset value
  • Vertical sliding safety glass sash
  • Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate
  • Gas phase bonded carbon filtration
  • Integral base with deep spill lip
  • Lab event timer
  • AirZone baffling to prevent fume hood roll and provide superior containment of gases and vapors
  • ASHRAE 110 tested
  • Deep base effectively contains accidental spills
  • Electronic gas detection for real-time gas phase filter monitoring
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Filter safety lockout to ensure correct filter replacement
  • Low airflow alarm warns the user both visually and audibly
  • Real time monitoring of installed filtration bed
  • Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1

 

HOW IT WORKS

Endeavour™ Ductless Fume Hood - Sliding Sash Airflow Diagram

Endeavour™ Ductless Fume Hood - Sliding Sash Airflow

  1. A
    Room air flows away from the operator and enters the enclosure in a horizontal pattern.
  2. B
    Room air mixes with both lighter and heavier gases.
  3. C
    Mixed air is drawn into the AirZone™ baffling.
  4. D
    Contaminated air is directed through the filtration bed.
  5. E
    Clean air is recirculated into the room.

 

OPTIONS

  • Access port for electrical cords
  • Deck-mounted fixtures
  • Polypropylene laboratory sinks
  • ULPA filter
  • Wall mounted fixtures and taps
  • Custom access ports for routine equipment maintennce
  • Duplex electrical outlets
  • Sturdy stand with leveling feet
  • Vented and unvented polypropylene base cabinets

 

DIMENSIONS

Product # External
Width Depth Height
ACPT3000S36"30"60"
ACPT3036S36"36"60"
ACPT4000S48"30"60"
ACPT4036S"36"60"
ACPT6000S72"30"60"
ACPT6036S72"36"60"
ACPT8000S96"30"60"
ACPT8036S96"36"60"
Product # Internal
ACPT3000S30"25"36"
ACPT3036S30"31"36"
ACPT4000S44"25"36"
ACPT4036S44"31"36"
ACPT6000S66"25"36"
ACPT6036S66"31"36"
ACPT8000S90"25"36"
ACPT8036S90"31"36"

 

CERTIFICATIONS

ASHREA110 certification

UL-CSA-CE certification

  