OPERATOR PROTECTION

Polypropylene Ductless Fume Hood - Folding Sash

Polypropylene Ductless Fume Hood - Folding Sash

A ductless solution for most common applications

 

PRODUCT DESCRIPTION

  • Thermally fused structural polypropylene for superior chemical resistance
  • AirSafe automatic safety controller
  • AirZone baffling system for advanced fume containment
  • Intergrated solid state gas detection
  • Single wall structure polypropylene design to maximize work area
  • Folding polycarbonate sash that allow free range of monitor for application manipulation

 

FEATURES

  • AirSafe™ automatic safety controller
  • No ductwork required
  • No installation required - plugs directly into a standard 110V or 220V electrical outlet
  • AirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood
  • Polypropylene construction for chemical resistance. The result: NO RUST
  • Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate
  • Integral vapor-proof fluorescent lighting
  • Large capacity filtration bed to handle a wide variety of applications
  • Gas phase bonded carbon filtration
  • Integral base with deep spill lip
  • Lab event timer
  • AirZone baffling to prevent fume hood roll and provide superior containment of gases and vapors
  • Brushless, sparkless blower is post-filter
  • Deep base effectively contains accidental spills
  • Electronic gas detection for real-time gas phase filter monitoring
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Filter safety lockout to ensure correct filter replacement
  • Low airflow alarm warns the user both visually and audibly
  • Real time monitoring of installed filtration bed
  • Tested to UL 61010-1 and CSA C22.2 No. 61010-1

 

HOW IT WORKS

Polypropylene Ductless Fume Hood - Folding Sash Airflow Diagram

Polypropylene Ductless Fume Hood - Folding Sash Airflow

  1. A
    Room air flows away from the operator and enters the enclosure in a horizontal pattern.
  2. B
    Room air mixes with both lighter and heavier gases.
  3. C
    Mixed air is drawn into the AirZone™ baffling.
  4. D
    Contaminated air is directed through the filtration bed.
  5. E
    Clean air is recirculated into the room.

 

OPTIONS

  • Polypropylene laboratory sinks
  • Vented and unvented polypropylene base cabinets
  • Sturdy stand with leveling feet
  • ULPA filter
  • Access port for electrical cords
  • Deck-mounted fixtures
  • Custom access ports for routine equipment maintennce

 

DIMENSIONS

Product # External
Width Depth Height
AC300036"30"54"
AC303636"36"54"
AC400048"30"54"
AC403648"36"54"
AC500060"30"54"
AC503660"36"54"
AC600072"30"54"
AC603672"36"54"
Product # Internal
AC300035"26"35"
AC303635"32"35"
AC400047"26"35"
AC403647"32"35"
AC500059"26"35"
AC503659"32"35"
AC600071"26"35"
AC603671"32"35"

 

CERTIFICATIONS

UL-CSA certification

  