OPERATOR PROTECTION

Polypropylene Ductless Fume Hood - Sliding Sash

Polypropylene Ductless Fume Hood - Sliding Sash

The look and feel of a traditional fume hood, without the associated installation or energy costs

 

PRODUCT DESCRIPTION

  • Thermally fused structural polypropylene for superior chemical resistance
  • AirSafe automatic safety controller
  • AirZone baffling system for advanced fume containment
  • Intergrated solid state gas detection
  • Dual wall design to allow for placement of fixtures, taps and electrical outlets like a typical total exhaust fume hood
  • Vertical sliding safety glass sash fitted with molded airfoil

 

FEATURES

  • AirSafe™ automatic safety controller
  • AirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood
  • Polypropylene construction for chemical resistance. The result: NO RUST
  • Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate
  • No installation required - plugs directly into a standard 110V or 220V electrical outlet
  • Integral vapor-proof fluorescent lighting
  • Dual wall construction allows for front mounting of services such as water, gas, or electric
  • Vertical sliding safety glass sash
  • Structural thermally-fused polypropylene construction for superior chemical resistance and spill containment
  • Constant monitoring of fume hood face velocity with variable airflow control to user preset value
  • Large capacity filtration bed to handle a wide variety of applications
  • Gas phase bonded carbon filtration
  • Integral base with deep spill lip
  • Lab event timer
  • AirZone baffling to prevent fume hood roll and provide superior containment of gases and vapors
  • ASHRAE 110 tested
  • Brushless, sparkless blower is post-filter
  • Deep base effectively contains accidental spills
  • Electronic gas detection for real-time gas phase filter monitoring
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Filter safety lockout to ensure correct filter replacement
  • Low airflow alarm warns the user both visually and audibly
  • Real time monitoring of installed filtration bed
  • Tested to UL 61010-1 and CSA C22.2 No. 61010-1

 

HOW IT WORKS

Polypropylene Ductless Fume Hood - Sliding Sash Airflow Diagram

Polypropylene Ductless Fume Hood - Sliding Sash Airflow

  1. A
    Room air flows away from the operator and enters the enclosure in a horizontal pattern.
  2. B
    Room air mixes with both lighter and heavier gases.
  3. C
    Mixed air is drawn into the AirZone™ baffling.
  4. D
    Contaminated air is directed through the filtration bed.
  5. E
    Clean air is recirculated into the room.

 

OPTIONS

  • Vented and unvented polypropylene base cabinets
  • Duplex electrical outlets
  • Custom access ports for routine equipment maintennce
  • Sturdy stand with leveling feet
  • Access port for electrical cords
  • Polypropylene laboratory sinks
  • Wall mounted fixtures and taps
  • ULPA filter

 

DIMENSIONS

Product # External
Width Depth Height
AC3000S36"30"60"
AC3036S36"36"60"
AC4000S50"30"60"
AC4036S50"36"60"
AC6000S72"30"60"
AC6036S72"36"60"
AC8000S96"30"60"
AC8036S96"36"60"
Product # Internal
AC3000S30"25"36"
AC3036S30"31"36"
AC4000S44"25"36"
AC4036S44"31"36"
AC6000S66"25"36"
AC6036S66"31"36"
AC8000S90"25"36"
AC8036S90"31"36"

 

CERTIFICATIONS

ASHREA110 certification

UL-CSA certification

  