AirClean® Systems AC600 Series PCR Workstations combine ISO 5 HEPA-filtered air with UV light irradiation for the ultimate DNA/RNA manipulation and amplification work area. Cross-contamination during amplification of DNA and RNA can lead to results that are inaccurate, costing the lab technician valuable time and reagents. PCR Workstations minimize this risk by keeping airborne contaminants away from samples and irradiating work surfaces and tools between amplifications.

PCR is a registered trademark of Hoffman-LaRoche

 

FEATURES

  • UVTect™ microprocessor controller
  • No installation required - plugs directly into a standard 110V or 220V electrical outlet
  • ISO 5 vertical laminar flow air
  • No ductwork required
  • UV shelf with built-in pipettor holder
  • Seamless plastic design -no joints or gaps in construction
  • Lab event timer
  • Available in standard height or tall version
  • Clear polycarbonate shell for 360° visibility
  • Extremely quiet operation < 49dBA
  • UV and fluorescent lights
  • Digital UV light timer :01-59 minutes
  • Access port for electrical cords
  • Automatic sash switch turns blowers off when sash is closed, maintaining an air barrier
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Filter safety lockout to ensure correct filter replacement
  • ISO 5 tested
  • Low airflow alarm warns the user both visually and audibly
  • Overlapping polycarbonate sash to prevent UV light exposure
  • Polycarbonate and polypropylene design reflects UV energy
  • Real time monitoring of installed filtration bed
  • Sash safety switch automatically turns off UV light and activates the blower when sash is raised
  • Shipped fully assembled
  • Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1

 

HOW IT WORKS

Combination PCR Workstation Airflow Diagram

Combination PCR Workstation Airflow

  1. A
    Room air enters and is cleaned via electostatic pre-filtration
  2. B
    Air then moves downward through the HEPA filter.
  3. C
    Clean vertical laminar flow air enters the chamber.
  4. D
    Clean air is recirculated into the room.

 

OPTIONS

  • Sturdy cart/trolley with locking casters for mobility
  • Hard surface disinfectant
  • ULPA filter

 

DIMENSIONS

Product # External
Width Depth Height
AC624LFUV24"24"30"
AC632LFUVC32"24"30"
AC632TLFUVC32"24"39"
AC648LFUVC48"24"32"
AC648TLFUVC48"24"42"
Product # Internal
AC624LFUV23"23"18"
AC632LFUVC31"23"18"
AC632TLFUVC31"23"27"
AC648LFUVC47"23"18"
AC648TLFUVC47"23"29"

UVTect Controller not available on AC624LFUV

 