PharmaSafe™ Ductless Class II Recirculating Enclosure

PharmaSafe™ Ductless Class II Recirculating Enclosure

Protection from toxic compounds

 

PRODUCT DESCRIPTION

AirClean® Systems PharmaSafe ductless enclosure provides protection to the operator and the environment while protecting the process. PharmaSafe is constructed of all white, thermally-fused polypropylene to prevent cracks and crevices that may promote bacteria or spore growth. Polypropylene construction makes the PhamaSafe easy to clean and maintain.

PharmaSafe's microprocessor controller monitors airflow and HEPA filters constantly. Airflow and filter conditions are displayed on an alphanumeric readout.

PharmaSafe's compact design allows it to easily fit onto a standard countertop. PharmaSafe measures only 36 inches wide with a nominal depth of 30 inches. The front opening is designed to close fully to prevent contaminants from entering the enclosure when not in use. A door position switch turns on the blowers when the door is opened.

 

FEATURES

  • ISO 5 vertical laminar flow air
  • Integral vapor-proof fluorescent lighting
  • Structural thermally-fused polypropylene construction for superior chemical resistance and spill containment
  • UVTect™ microprocessor controller
  • Lab event timer
  • Filter safety lockout to ensure correct filter replacement
  • Low airflow alarm warns the user both visually and audibly
  • Exhaust air is HEPA filtered, keeping any potential particulate from returning to the room
  • Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
  • Real time monitoring of installed filtration bed

 

HOW IT WORKS

PharmaSafe™ Ductless Class II Recirculating Enclosure Airflow Diagram

PharmaSafe™ Ductless Class II Recirculating Enclosure Airflow

  1. A
    Room air enters and is pulled into the lower baffle along with a portion of the chamber air. Air travels through the lower baffle and up the rear baffle.
  2. B
    Chamber air is mixed with room air.
  3. C
    Contaminated air is directed through the filtration bed.
  4. D
    The majority of air moves through the HEPA filter which provides ISO 5 clean air to the chamber.
  5. E
    Remaining air is HEPA filtered and exits the enclosure.

 

OPTIONS

  • ULPA filter

 

DIMENSIONS

Product # External
Width Depth Height
ACPHS3636"30"45"