Endeavour™ Ductless Fume Hood - Folding Sash

Endeavour™ Ductless Fume Hood - Folding Sash Endeavour™ Ductless Fume Hood - Folding Sash Endeavour™ Ductless Fume Hood - Folding Sash Endeavour™ Ductless Fume Hood - Folding Sash
Endeavour with Folding Sash

Monitoring and fume hood control at the touch of an icon

Featuring the AirSafe® NXT Automatic Safety Controller
AirSafe NXT

Request Quote

Application Worksheet

Endeavour ductless fume hoods provide the operator with user-friendly controls, superior construction materials and market-leading safety features needed for effective fume containment. Endeavour ductless fume hoods can be placed virtually anywhere, without the need to connect to building infrastructure, giving you the flexibility expected from modern laboratory equipment.

Features
Integral base with deep spill lip
No installation required - plugs directly into a standard 110V or 220V electrical outlet
Wide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate
AirZone baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating "dead spots" within the hood
Structural thermally-fused polypropylene construction for superior chemical resistance and spill containment
Constant monitoring of fume hood face velocity with variable airflow control to user preset value
Built-in solid state gas detection
Large capacity filtration bed to handle a wide variety of applications
Touch-screen microprocessor control with variable airflow controller and constant filter monitoring
ChemMinder™ chemical class confirmation - user notification of chemical/filtration compatibility
Lab event timer
Gas phase bonded carbon filtration
Benefits
Filter safety lockout to ensure correct filter replacement
AirZone baffling to prevent fume hood roll and provide superior containment of gases and vapors
Electronic gas detection for real-time gas phase filter monitoring
Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1
Brushless, sparkless blower is post-filter
Deep base effectively contains accidental spills
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
Low airflow alarm warns the user both visually and audibly
Real time monitoring of installed filtration bed
Options
Deck-mounted fixtures
Access port for electrical cords
Vented and unvented polypropylene base cabinets
Sturdy stand with leveling feet
ULPA filter
Custom access ports for routine equipment maintenance
Polypropylene laboratory sinks
Product # External
Width Depth Height
ACPT3000 36" 30" 54"
ACPT3036 36" 36" 54"
ACPT4000 48" 30" 54"
ACPT4036 48" 36" 54"
ACPT5000 60" 30" 54"
ACPT5036 60" 36" 54"
ACPT6000 72" 30" 54"
ACPT6036 72" 36" 54"
Product # Internal
ACPT3000 35" 26" 35"
ACPT3036 35" 32" 35"
ACPT4000 47" 26" 35"
ACPT4036 47" 32" 35"
ACPT5000 59" 26" 35"
ACPT5036 59" 32" 35"
ACPT6000 71" 26" 35"
ACPT6036 71" 32" 35"

How it Works

  • A

    Room air flows away from the operator and enters the enclosure in a horizontal pattern.

  • B

    Room air mixes with both lighter and heavier gases.

  • C

    Mixed air is drawn into the AirZone™ baffling.

  • D

    Contaminated air is directed through the filtration bed.

  • E

    Clean air is recirculated into the room.

Air Flow Diagram

Request Catalog

Request Pricing

AirClean Systems Products In Action