Name: Polypropylene Ductless Fume Hood - Folding Sash
Description: Polypropylene ductless fume hoods protect both the operator and the environment by filtering toxic fumes, vapors, or gases through AirClean® Systems’ proprietary bonded carbon filtration. Standard with a thermally-fused integral spill tray, polypropylene ductless fume hoods are chemically resistant to virtually all corrosive applications.
Available Options:
Name: Dead Air Box
Description: AirClean® Systems dead air boxes provide a circulation-free environment for the amplification and manipulation of DNA/RNA. Each dead air box is standard with the UVTect Microprocessor controller and a 254nm ultraviolet light source for irradiation between amplifications. A safety interlock switch disables the UV light when the sash is raised, preventing operator exposure. Seamless design and UV-reflective construction materials further ensure no harmful UV energy escapes the enclosure.
Available Options:
Name: Vertical Laminar Flow Workstation
Description: AirClean® Systems AC600 Series vertical laminar flow workstations are ideal for non-hazardous applications that require a clean work area. These compact, lightweight workstations provide positive-pressure, ISO 5 air throughout the chamber and sash opening, thus keeping airborne particulate away from sensitive applications. Given the small footprint and ease of installation (simply plug in the power cord), the AC600 Series vertical laminar flow workstations are an excellent choice for mobile ‘clean zones’ within your facility.
Available Options:
Name: Combination PCR Workstation
Description: AirClean® Systems AC600 Series PCR Workstations combine ISO 5 HEPA-filtered air with UV light irradiation for the ultimate DNA/RNA manipulation and amplification work area. Cross-contamination during amplification of DNA and RNA can lead to results that are inaccurate, costing the lab technician valuable time and reagents. PCR Workstations minimize this risk by keeping airborne contaminants away from samples and irradiating work surfaces and tools between amplifications.
Available Options:
Name: AC600 Series UPUV Class 1 Biological Safety Workstation
Description: The AC600 Series UPUV workstation is designed to safely handle of biological samples as well as a safe area to open small packages. The UPUV workstation protects the operator from exposure to airborne pathogens and provides UV-C light for decontamination of materials and the work area. The UPUV workstation uses proven HEPA technology for capturing potentially harmful toxins. All UPUV workstations are leak tested and certified, at our factory, with a 0.2 to 0.5 micron aerosol and then scanned for bypass. Units carry certification results for future verification.
Available Options:
Name: AC600 Series Ductless Chemical Workstation
Description: The AC600 Series ductless chemical workstation is a low cost, operator protection product that protects the end user from toxic vapors, gases, fumes and particulate. Smaller and more mobile than a standard ductless fume hood, AC600 Series ductless chemical workstations are the perfect solution for performing low-volume applications with known chemicals. These products come standard with the same advanced safety features and technology as larger AirClean® Systems ductless hoods: gas phase bonded carbon filtration, real-time gas detection and constant airflow control and monitoring.
Available Options:
Name: PowderSafe™ Type A Enclosure
Description: PowderSafe Type A enclosures provide a safe and effective weighing environment for toxic compounds and/or liquid chemicals. Engineered specifically for balances, PowderSafe Type A enclosures protect the operator by capturing particulate in HEPA filtration without sacrificing balance stability. These compact, ductless enclosures are factory leak tested, certified and shipped fully assembled for simple installation on any countertop.
Available Options:
Name: PowderSafe™ Type B Enclosure
Description: Seamless polypropylene construction provides the mass and vibration resistance crucial for accurate powder weighing, while the AirSafe™ automatic safety controller monitors airflow and filter conditions. The full rear-wall HEPA filtration zone moves powders and particulate away from the operator in a smooth horizontal laminar pattern. HEPASafe™ technology allows filters to be safely and easily bagged-out under negative pressure.
Available Options:
Name: PowderSafe™ Type C Enclosure
Description: AirClean® Systems Type C PowderSafe ductless balance enclosures incorporate the airflow dynamics and HEPASafe™ features of the PowderSafe Type B with the user-friendly features and chemical fume containment capabilities of an AirClean Systems ductless fume hood. Thermally-fused polypropylene construction makes the PowderSafe Type C enclosure perfect for weighing powders or solvents.
Available Options:
Name: PowderSafe™ Bulk Handling Enclosure
Description: When effective powder containment is needed during bulk manipulation, the PowderSafe Bulk Handling enclosure is an economical and space-saving alternative to larger walk-in enclosures. With a unique drum access port incorporated into the base of the enclosure, the drum can be raised and sealed to the access port, effectively extending the enclosure’s containment area into the drum. Designed to provide a turbulence-free airflow environment, PowderSafe Bulk Handling enclosures move air in a horizontal pattern to maximize containment while minimizing sample loss and balance instability.
Available Options:
Name: AC-DS-03 Neutralizer Station
Description: AirClean® Systems AC-DS-03 neutralization station is a semi-automated system for neutralizing high-level disinfectants such as glutaraldehyde and OPA, prior to disposal into facility drains. The large reservoir holds up to four gallons of disinfectant per neutralization cycle. Devices capable of pumping spent disinfectant, such as the AC600 endoscopy workstation with GlutAway™ pump, can be connected to the AC-DS-03, eliminating operator exposure when transferring disinfectant for neutralization.
Terms and Conditions Apply: